SR1406 UV Tube Flame Sensor — R9533 Replacement Evaluation
Sartec Photoelectronics offers the SR1406 UV tube flame sensor for flame and discharge detection projects. The published Sartec catalog lists Hamamatsu R9533 as a reference model. Use that reference to begin a model-specific engineering evaluation; it does not establish a verified drop-in replacement or approval for a complete flame detection system.
Key Features
- Published catalog includes a dedicated SR1406 section and a mechanical drawing.
- The catalog lists a 185–260 nm spectral response range.
- The catalog lists a 350 ± 25 V operating voltage. Confirm the current model revision and driving circuit before specifying the component.
- R9533 is an evaluation reference; electrical, mechanical and application suitability requires documented review.
Typical Applications
The catalog identifies flame and discharge detection applications, including burner combustion monitoring and industrial UV monitoring. Suitability for a particular installation depends on the complete sensing circuit, optical path, mounting and controller.
Technical Overview
Source: the SR1406 section on PDF page 4 (printed page 5) of the linked Sartec catalog. The file URL contains 2026, while its contents page says “SarTEC Product Catalog 2025”. These are attributed catalog values; confirm the current datasheet revision before circuit design or ordering. Do not apply SR1406i or another model’s specifications to SR1406. This section does not provide verified absolute maximum limits or complete drive-circuit requirements.
Published SR1406 Catalog Values
| Parameter | Value |
|---|---|
| Model | SR1406 |
| Spectral response range | 185–260 nm |
| Operating voltage | 350 ± 25 V |
| Reference model for evaluation | Hamamatsu R9533 |
R9533 Replacement Evaluation Checklist
Compare the exact original R9533 revision and its manufacturer documentation with the current SR1406 datasheet. The reference listing alone does not prove equal sensitivity, lifetime, pinout or controller compatibility.
| Review area | Required comparison |
|---|---|
| Electrical | Compare operating voltage, current limits, start and sustaining behavior, and quenching requirements. |
| Mechanical | Compare the model-specific drawing, leads, socket, orientation and installation clearances. |
| Optical and system | Check spectral response, viewing geometry, controller signal behavior and required flame tests. |
| Acceptance | Record the application, revisions, any adaptations and sample-validation results before approving replacement. |
FAQs
Can SR1406 be evaluated as an alternative to Hamamatsu R9533?
Where is the SR1406 UV tube flame sensor used?
Can Sartec Photoelectronics help with cross-reference selection?
Related Model and Engineering Resources
Request an R9533 replacement evaluation
Request a model-specific replacement evaluation. Send the original model and revision, controller or amplifier, supply voltage, drawing or photos, application conditions and required quantity.
R9533 Replacement Evaluation — Engineering Review
Concise selection notes for engineers, buyers, and maintenance teams before sampling or replacement review.
Compare the exact original R9533 revision and its manufacturer documentation with the current SR1406 datasheet. The reference listing alone does not prove equal sensitivity, lifetime, pinout or controller compatibility.
When evaluating R9533 replacement evaluation, check the target model, mounting condition, electrical interface, response characteristics, operating temperature, amplifier compatibility, and the extent of electrical or mechanical adaptation required by the application.
Related resources include UV flame detectors, CHECK LIGHT UV flame sensors, and engineering support. For broader combustion safety context, engineers may also review NFPA.