SR0708 UV Phototube – Component Evaluation
The Sartec SR0708 is a UV phototube for component-level evaluation in industrial flame detection equipment. Select it using the original tube identification, operating circuit and mechanical drawing.
For a complete C7027 detector assembly evaluation, review SR79A. Component and assembly requirements should be assessed separately.
Browse the UV Tube Flame Sensors range or consult the SR0708 catalog entry.
Key Features
- UV phototube component for circuit-level selection
- Requires an appropriate operating circuit and signal processing
- Tube dimensions, connections and operating conditions require comparison
Typical Applications
• Industrial gas burners
• Combustion monitoring systems
• Boilers and furnaces
• Industrial safety and flame supervision systems
Technical Overview
Evaluate the phototube together with its drive circuit, signal processing, optical arrangement and enclosure. Request the model-specific electrical data and drawing before selecting a component for an existing detector.
Specifications and Evaluation Scope
| Parameter | SR0708 review | Reference |
|---|---|---|
| Product form | UV phototube component | Sartec catalog, page 4 |
| Original tube mapping | Requires engineering confirmation | Exact tube part number and drawing |
| Operating circuit | Model-specific review required | Tube and controller data |
| Application | Industrial UV flame detection equipment | System validation required |
SR0708 Component and Honeywell Detector Assemblies
Overview
SR0708 is supplied as a phototube component. Honeywell C7027A and C7035A are complete flame detectors. Their model families identify the original assembly, while a tube comparison requires the internal component identification.
Component and Assembly Review
The comparison below separates the product levels so that enquiries include the correct assembly or component information.
| Review item | SR0708 | Honeywell reference |
|---|---|---|
| Product level | UV phototube component | C7027A / C7035A detector assembly |
| Selection identity | Tube drawing and circuit data | Complete detector suffix and original tube identity |
| Service approach | Evaluate the intended component installation | Use the exact detector service instructions |
| Interchange status | Requires engineering verification | Family name alone is insufficient |
Performance Summary
The current SR0708 review establishes its component role. Confirm the tube identity and operating conditions before drawing conclusions about a specific replacement or performance comparison.
Related UV Tube Flame Sensors:
For applications requiring alternative UV tube flame sensor models, the following Sartec products may also be considered:
• SR08 – R2868 Equivalent
• SR07 – R259 Equivalent
• SR1309 – R9454 Equivalent
Identify the Original Detector and Sensing Tube
Record the original detector suffix, internal tube markings and component drawing. The Sartec catalog cross-reference is a starting point for an enquiry, while specific tube interchange remains to be confirmed.
FAQs
Is SR0708 a complete flame detector?
SR0708 is a UV phototube component. Assembly selection requires a separate detector-level review.
Can SR0708 be selected by the C7027 or C7035 family name alone?
Identify the complete detector suffix and original sensing-tube part number. Sartec has not confirmed a specific tube interchange for this review.
What information is needed for a component evaluation?
Provide the tube drawing, dimensions, connections, operating circuit, controller and amplifier models, and intended operating conditions.
What must be checked before use?
Qualified personnel should validate electrical and mechanical compatibility, flame signal and the required system safety checks using the equipment procedures.
Why Review the UV Phototube Separately?
A component evaluation compares tube geometry, connections, drive conditions and output behaviour. For C7027A, Honeywell specifies assembly replacement because its internal UV tube is not field replaceable. C7035A service information lists replaceable UV tubes. Follow the instructions for the exact original detector.
Honeywell Minipeeper product data · Sartec SR0708 catalog entry
SR0708 Industrial UV Detection Applications
The Sartec catalog lists boiler combustion flame detection and industrial UV monitoring as SR0708 application areas. Suitability depends on the complete detector design and the validated operating conditions.
Electrical and Mechanical Integration Review
Compare tube dimensions and connections, operating voltage, drive circuit and signal-processing input. Record the enclosure, temperature and optical arrangement used in the intended detector design.
Separate the component operating limits from the ratings of the complete enclosure, wiring and controller. Request the applicable SR0708 technical document through the download center or engineering support.
SR0708 Evaluation and Validation Scope
Define the proposed use as a new detector design, component evaluation or complete assembly replacement. Document the required tests and the person responsible for approving the integrated system.
Documents for an Engineering Review
Send the original tube identification, drawing, controller and amplifier models, circuit details and intended operating conditions for a component review.
SR0708 Engineering Review
Concise selection notes for engineers, buyers, and maintenance teams before sampling or replacement review.
Review SR0708 using the original tube identification, circuit information and mechanical drawing. Document the proposed installation and the validation required before selecting a component.
When evaluating SR0708, check the target model, mounting condition, electrical interface, response characteristics, operating temperature, amplifier compatibility, and the extent of electrical or mechanical adaptation required by the application.
Related resources include UV flame detectors, CHECK LIGHT UV flame sensors, and engineering support. For broader combustion safety context, engineers may also review NFPA.
UV sensor selection resources: compare UV tube flame sensors, review datasheets and technical documents, read the industrial flame detection application guide, or request an engineering compatibility review.