UV Tube Flame Sensors for Industrial Flame Detection
UV Tube Flame Sensor Series Overview
Sartec Photoelectronics supplies UV tube flame sensors for industrial flame detection and model-specific replacement evaluation. Use this page to compare the available model references, review the published SR08 and SR1309 specifications, and locate the corresponding datasheets.
A UV tube is a sensing component. Its suitability depends on the driving circuit, mounting, optical path, operating environment and flame amplifier or controller. A reference-model listing identifies an evaluation starting point; it does not establish a verified drop-in replacement or approval for a complete burner safety system.
UV Tube Flame Sensor Reference Matrix
Use the following references to locate candidate models for an engineering review. Confirm the exact original part number, whether it is a sensing tube or detector assembly, and the relevant controller before evaluating replacement suitability.
| Sartec Model |
Reference Model for Evaluation |
Typical Use |
Link |
| SR08 |
Hamamatsu R2868 |
Industrial burners, boilers, combustion safety systems |
SR08 product page
|
| SR07 |
Hamamatsu R259 |
Industrial flame monitoring; confirm environmental limits |
SR07 product page
|
| SR0708 |
Honeywell C7035 / C7027 |
Industrial burners, boilers, combustion safety systems |
SR0708 product page
|
| SR1406 |
Hamamatsu R9533 |
Industrial combustion flame detection |
SR1406 product page
|
| SR1309 |
Hamamatsu R9454 |
Industrial combustion safety systems, UV flame monitoring |
SR1309 product page
|
| SR244 |
Hamamatsu R244 |
Industrial burners, boilers, furnace flame detection |
SR244 product page
|
| SR15A |
Siemens P578.61 |
Industrial combustion safety systems, long-term monitoring |
SR15A product page
|
| SR65 |
Application-led selection; no reference model listed |
Boiler flame monitoring; confirm system requirements |
SR65 product page
|
Note: Reference models are for evaluation only. For C7035 / C7027 projects, establish whether the request concerns a sensing element, assembly or complete detector; the listed component must not be assumed to replace the entire detector. Confirm electrical limits, mechanical fit, controller compatibility and application tests before acceptance.
Published SR08 and SR1309 Specifications
The two models below have model-specific datasheets linked from their product pages. The listed values are working voltages, not absolute maximum ratings. Do not apply one model’s voltage to another.
Both models require an external driving circuit. Review the complete datasheet and product page for current limits, quenching requirements and test conditions. These figures do not prove electrical or mechanical interchangeability with a reference model.
Selection Checks Before Ordering
- Confirm the exact model and current datasheet revision.
- Compare working voltage, absolute limits, spectral response and driving-circuit requirements.
- Check dimensions, leads, mounting, viewing path and environmental limits.
- Identify the flame amplifier or controller and its required signal behavior.
- Plan application tests before accepting a replacement candidate.
• Industrial gas burners
• Combustion monitoring systems
• Boilers and furnaces
• Industrial safety and flame supervision systems
Available Models & Evaluation References
Sartec Photoelectronics offers UV tube flame sensors for model cross-reference, maintenance replacement and new-system evaluation in industrial flame detection applications.
• SR08 – For evaluation against Hamamatsu R2868
• SR07 – For evaluation against Hamamatsu R259
• SR0708 – For evaluation against Honeywell C7035 / C7027
• SR1406 – For evaluation against Hamamatsu R9533
• SR1309 – For evaluation against Hamamatsu R9454
• SR244 – For evaluation against Hamamatsu R244
• SR15A – For evaluation against Siemens P578.61
• SR65 – For boiler flame-monitoring application review
Model-specific technical data is required for selection. This family page provides a reference index and direct access to the published SR08 and SR1309 datasheets; it does not assign their electrical or environmental limits to the other models.
For models without a verified public specification table, request the current datasheet and mechanical drawing before specifying a circuit or placing a replacement order.
Compatibility & Integration
Check the original sensor, driving voltage, current limit, quenching circuit, mechanical envelope and flame amplifier or controller. A UV sensing tube, a complete detector assembly and a controller have different replacement scopes.
A model reference alone does not establish pin-to-pin compatibility or system approval. Use a documented comparison and application tests to decide whether a candidate is suitable.
FAQ - UV Tube Flame Sensor Replacement
What is a UV tube flame sensor used for?
A UV tube flame sensor detects ultraviolet radiation from a flame and is commonly used in burner monitoring and combustion safety systems.
What must be checked before replacing a UV tube?
Engineers should verify spectral response, operating voltage, signal output, mechanical envelope, socket compatibility, controller requirements, and the target burner test procedure.
Are UV tube sensors interchangeable between brands?
Not automatically. Similar dimensions or function do not guarantee safe interchangeability, so model-level comparison and application validation are required.
When should a self-checking sensor be selected?
Self-checking designs are preferred where continuous burner operation, false flame prevention, or stricter safety logic is required.
Request a UV tube selection or replacement evaluation. Send the original model, controller or amplifier, supply voltage, mounting drawing or photos, application conditions and quantity required.
Engineering Review
Engineering Review Before RFQ
Concise selection notes for engineers, buyers, and maintenance teams before sampling or replacement review.
01The UV tube flame sensors page is a technical hub for engineers evaluating flame detection architecture, sensor families, replacement options, and application-specific selection requirements.
02For UV tube flame sensors, review flame characteristics, fuel type, burner geometry, detector position, response time, amplifier compatibility, environmental limits, and maintenance access before selecting a product.
03Relevant pages include UV flame detectors, CHECK LIGHT UV flame sensors, burner management systems, and engineering support.
No. UV tube sensors are sensing components, while integrated detectors may include housing, electronics, or signal processing features.
UV sensor selection resources: compare UV tube flame sensors, review datasheets and technical documents, read the industrial flame detection application guide, or request an engineering compatibility review.
UV flame detection sensor selection and replacement review
Review UV flame sensors by operating circuit, UV spectral response, mounting geometry, viewing path, flame amplifier compatibility, response behavior, and burner test procedure.
Related Engineering Selection Pages
Use these pages to compare adjacent sensor families, replacement options and application requirements before sending an RFQ.