M2012 Photon Counting Detector and M2021/M2031 PMT Modules

Sartec Photoelectronics offers three documented PMT module configurations for low-light detection. M2012 provides a photon-counting pulse output, M2021 provides a voltage output, and M2031 provides a current output. Select the output architecture to match the receiving instrument.

Choose the correct output architecture

ModelOutput and electrical requirements
M2012

Output: Photon-counting detector with positive TTL pulse output.

Supply: +4.75 to +5.25 V.

Spectral range: 290–650 nm.

M2021

Output: PMT light detector with current-to-voltage amplification.

Supply: Bipolar supply; positive and negative rail magnitudes 11.75–12.25 V.

Spectral range: 290–650 nm.

M2031

Output: PMT light detector with direct current output.

Supply: +11.75 to +12.25 V.

Spectral range: 290–650 nm.

These values are taken from the PMT Manual V3.1, printed pages 35, 37 and 39. Confirm the latest model-specific document, wiring diagram and supplied configuration before integration.

M2012/2021/2031 Photon Counter Detector (Analogue to H10682/H11720/H11721/H11902/CH345 by Hamamatsu)

M2012 photon-counting specifications

The manual lists the following values at a test temperature of 25°C. Use the complete table and footnotes when assessing the detector.

ParameterPublished value and condition
Effective area22 mm diameter
Peak wavelength420 nm
Count sensitivity4.5 × 10^5 s^-1·pW^-1 at 400 nm
Maximum linear count rate before correction1.0 × 10^7 s^-1
Count rate with correction4.0 × 10^7 s^-1 when used with the M4011 counting unit correction function
Dark countTypical 100 s^-1; maximum 200 s^-1, tested after 30 minutes of light avoidance
Pulse-pair resolution17 ns
Output pulse amplitudeTypical 2.2 V; maximum 2.5 V, with a 50-ohm load
Recommended load50 ohms
Operating temperature+5 to +40°C

The corrected count-rate figure must not be presented as an unconditional standalone M2012 count rate. M2021 and M2031 are different output configurations; this photon-counting table does not apply to them.

M2021 and M2031 integration

M2021 includes current-to-voltage amplification. M2031 provides a current output. Review the receiving circuit, gain control, bandwidth, load, power rails and connector assignments using the separate model pages in the manual. Do not connect either configuration using the M2012 pulse-output assumptions.

View PMT Manual V3.1

Industrial and Research Applications

Industrial Measurement Systems: Suitable for environments requiring high sensitivity and precision, such as factory automation, process monitoring, and instrumentation.

Medical Imaging: Ideal for imaging systems used in hospitals or diagnostic labs, where high accuracy and reliability in low-light performance are critical for detecting and analyzing medical conditions.

Spectroscopy: Excellent for scientific research, environmental monitoring, and analytical applications that require precise light signal detection and measurement.

 

FAQ – M2012, M2021 and M2031 PMT Modules

Can these PMT modules replace H10682/H11720/H11721/H11902/CH345 models?

Interchangeability is not established by model-family names. Send the full original part number and suffix. Compare output type, spectral response, effective area, supply rails, gain control, connector pinout, load, dimensions and measurement conditions; validate the selected configuration in the target instrument.

Which PMT module output should I choose?

These are low-light detector configurations for instrument projects. Select the architecture for the receiving instrument: M2012 pulse output, M2021 voltage output, or M2031 current output. Final application qualification is required.

How should compatibility with an existing instrument be evaluated?

Compatibility must be reviewed for the exact original model, power rails, pinout, receiving circuit and optical requirements. M2021 requires bipolar supply rails; M2031 uses a single positive supply.

Can one gain specification be applied to all three models?

Gain and gain-control requirements must be reviewed using each model’s separate manual section. A single common gain must not be assumed for all three configurations.

How do I select the right model for my application?

Send the full model number, wavelength, output architecture, circuit requirements, sample conditions and quantity. The PMT Manual V3.1 documents separate M2012, M2021 and M2031 sections.


 

Contact Us

For more information or to request a quote, please feel free to contact us directly. We’re happy to assist with product selection and provide additional details about our PMT solutions.

Engineering Review

M2012 photon counter detector Engineering Review

Concise selection notes for engineers, buyers, and maintenance teams before sampling or replacement review.

01

The M2012 photon counter detector page supports engineers reviewing photomultiplier tube options, photon counting requirements, equivalent model selection, and integration needs for industrial or scientific instruments.

02

For M2012 photon counter detector, compare spectral response, gain, dark current, operating voltage, socket compatibility, circuit design, package constraints, and detector environment.