Sartec Photoelectronics Contact Us
UV Tube Flame Sensor

SR244 UV Tube Flame Sensor — R244 Replacement Evaluation

Sartec Photoelectronics supplies the SR244 UV tube flame sensor for flame detection projects. Its model-specific published datasheet lists a 500 ± 50 V DC power supply voltage and a 185–260 nm spectral response range. Hamamatsu R244 is a reference for replacement evaluation; confirm the driving circuit, mechanical fit and controller requirements before accepting a substitute.

R244 evaluation reference 185–260 nm 500 ± 50 V DC External driving circuit
Need a precise match check? Send your existing controller or amplifier model and application details to verify compatibility.
SR244 UV tube flame sensor for R244 replacement evaluation
Evaluation Reference
Hamamatsu R244
Sensor Type
UV Tube Flame Sensor
Output Mode
External driving circuit
Typical Use
Boilers / Furnaces / Burners
Reference Model for Evaluation
Hamamatsu R244
Sensor Type
UV Tube Flame Sensor
Output Mode
External circuit; verify controller interface
Typical Applications
Industrial Burners, Boilers, Combustion Safety Systems

Key Features

  • Direct access to the model-specific SR244 datasheet in PNG format.
  • Published spectral response range: 185–260 nm.
  • Published power supply voltage: 500 ± 50 V DC; this differs from the listed 575 V maximum rating.
  • The datasheet includes a mechanical drawing and an example operating circuit with pulse output. Review all component values, limits and notes before integration.

Typical Applications

The published SR244 datasheet lists boiler combustion monitoring and facility fire detection. Selection for a particular burner or monitoring system requires review of the optical path, circuit, controller and operating environment.

Technical Overview

Source: the linked SR244 datasheet, headed “SR244 (Analogous to R244)”. The 575 V value is a maximum rating, not a recommended working voltage. Review the full sheet, circuit and footnotes; average discharge current is not an output-interface compatibility specification. No revision date was identified on the published sheet. Confirm the current document before design or ordering.

Published SR244 Specifications

ParameterValue
ModelSR244
Spectral response range185–260 nm
Power supply voltage (operating parameter)500 ± 50 V DC
Average discharge current (operating parameter)0.3 mA
Minimum quenching time1 ms
Power supply voltage — maximum rating575 V DC
Driving circuitExternal circuit; example circuit shown in datasheet
Reference model for evaluationHamamatsu R244
Need a precise match check? Send your existing controller, amplifier model, and application details—Sartec Photoelectronics can help verify compatibility.

R244 Replacement Evaluation Checklist

Use the current R244 manufacturer datasheet and the SR244 model-specific sheet to compare electrical, mechanical, optical and controller requirements. A reference listing does not establish proven equivalence.

Review areaRequired comparison
Operating circuitCompare operating voltage, current limits, quenching behavior and signal-conditioning requirements.
Mechanical fitCompare dimensions, leads, electrode orientation and mounting against both drawings.
Controller and opticsVerify pulse detection, amplifier thresholds, optical path and response in the intended flame-monitoring system.
QualificationDocument the original part revision, any circuit or mounting adaptations and application test results before accepting a replacement.

Performance Summary

The published SR244 datasheet provides model-specific operating values, dimensions and a circuit example. Confirm the full circuit and application conditions, then validate samples before accepting an R244 replacement.

Compatibility and Qualification

Treat R244 as a reference for a documented replacement evaluation. Electrical, mechanical, optical and controller compatibility require review and application tests before approval.

FAQs

What is the published SR244 operating voltage?
The SR244 datasheet lists 500 ± 50 V DC as its power supply voltage under operating parameters. Its separate 575 V maximum rating is not a recommended working voltage. Review the full circuit and footnotes before use.
Is SR244 a verified drop-in replacement for Hamamatsu R244?
The published sheet identifies R244 as an analogous reference. That does not establish drop-in or pin-to-pin compatibility. Review electrical limits, circuit, leads, mounting, controller requirements and application test results before approval.
Does SR244 require an external circuit?
Yes. The datasheet shows an external operating circuit and a pulse-output example. Confirm circuit values, quenching time, current limits and compatibility with the target flame amplifier or controller.
Is the SR244 datasheet a PDF?
The current model-specific datasheet linked here is a PNG image. Open “View SR244 Datasheet (PNG)” to review the specifications, dimensions, circuit and notes.

Related Model and Engineering Resources

Technical Support

Request an R244 replacement evaluation

Request a model-specific replacement evaluation. Send the original model and revision, controller or amplifier, supply voltage, drawing or photos, application conditions and required quantity.

Engineering Review

R244 Replacement Evaluation — Engineering Review

Concise selection notes for engineers, buyers, and maintenance teams before sampling or replacement review.

01

Use the SR244 datasheet and the original R244 documentation to prepare a model-specific engineering comparison. Reference listings do not establish verified interchangeability.

02

For R244 replacement evaluation, check the target model, detector type, mounting condition, electrical interface, response time, flame amplifier compatibility, cable routing, and ambient temperature.